Övriga tillbehör
2AB125R is a DIP resistor of 125 ohm with a tight 0.1% tolerance and a 1/4 W power rating. Its metal film construction gives a temperature coefficient of 50 ppm/℃, which suits circuits where a stable, well-defined resistance value matters.Engineers typically choose this part when a precise fixed value is needed on a DIP-format board, and the RoHS certification is relevant where compliant components are specified.Resistance: 125 ohmTolerance: 0.1%Power rating: 1/4 WTemperature coefficient: 50 ppm/℃
AFAN-02 CR is a 1U two-way cooling fan module that keeps equipment within its temperature limits by providing active air movement. It accepts two fan modules, so a failed unit can be replaced while the system keeps running.Each fan has its own fault LED, and the relay alarm output signals a fan failure or loss of power. A failure in one fan does not affect the other, and a 5A fuse with overvoltage protection guards the 24 VDC supply.Relay alarm output reports fan failure or power loss to a remote monitoring systemMounted on a wall, the unit is suited to small server cabinetsApplicationsCooling for small server cabinets
The AFAN-04 CR is a 1U cooling fan module for rack-mounted computer room and industrial equipment. It houses four fans that provide active airflow, helping to lower the operating temperature of the equipment and maintain stable operation.Each fan has its own fault LED, and a relay alarm output signals any fan failure or loss of power to a remote monitoring system. Because a single fan failure does not affect the others, the module keeps cooling while a faulty unit is identified and replaced. The fans are hot-swappable, so maintenance can be carried out without shutting down the equipment.The module runs from 24 VDC with a 5A fuse for overvoltage protection and is sized for 19-inch racks. It is suited to engineers specifying thermal management for server rooms and control cabinets, where fan faults must be detected early to avoid overheating.ApplicationsCooling of computer room and server room equipmentThermal management of industrial equipment in 19-inch cabinetsFan fault monitoring with remote alarm signalling
One Additional THIN CLIENT.
The BX-ENEL5-1 CR is a battery box that holds a Nikon ENEL5 battery. It is designed to be fitted on a DIN rail, so it can be installed in a control cabinet or equipment rack alongside other automation hardware. The user must insert the Nikon ENEL5 battery before use.A 15 cm cable is included for connecting the battery box to the equipment it serves. The compact housing measures 56mm (width) x 75mm (length) x 16mm (height), which keeps the footprint small on a crowded DIN rail.The BX-ENEL5-1 CR is certified to RoHS and WEEE. Check the dimensions and cable length against your installation before ordering.
CD-002 is a split ferrite core for suppressing electromagnetic and radio-frequency interference on round cables. Its hinged plastic case closes around the cable and holds the ferrite securely in place, so it can be fitted without re-terminating the cable.The core is aimed at low-frequency noise generated by engine control units, inverters and motors. It can be retrofitted to installed equipment or added during post-assembly work on the data and power cables of electronic devices, which suits environments where EMI or RFI affects signal integrity.Each package contains 10 cores, supplied in white and rated for an operating temperature of -40 °C to 75 °C. Maximum cable diameter is Ø13 mm.ApplicationsSuppressing low-frequency noise from engine control unitsReducing noise from inverters and motorsReducing EMI and RFI on data cables of electronic equipmentReducing EMI and RFI on power cables of electronic equipmentRetrofitting existing installations
Dust-laden outdoor air can block the measuring channel of a PM2.5 sensor. Once clogged, the sensor reports heavy concentrations and keeps alarming, and the readings can no longer be trusted.FLT-C001 is a circular replaceable filter patch designed for the CL-210 and DL-1000 series. Engineers can change the patch in the field without removing the device from its installation, which keeps downtime and repair costs down compared with sending a clogged module back for repair.Supplied as a pack of four patches, each measuring OD 16 mm and ID 12 mm. The patches are RoHS and WEEE certified.ApplicationsOutdoor PM2.5 air quality monitoringDusty environments where the PM2.5 sensor inlet is prone to clogging
The FLT-C002 is a replacement filter patch for the CL-220 series PM2.5 sensor modules. Outdoor installations collect dust and aerosol that can block the sensor's measuring channel, which leads to continuous high-concentration alarms and unreliable readings. This pack of four rectangular patches allows the blocked element to be changed in the field.Because the patch can be replaced without uninstalling the device, maintenance is quicker and the module does not need to be sent back to the factory for repair. This reduces repair costs and avoids the downtime that normally accompanies a return-to-factory service.Sold as a pack of four patches, each measuring W27 x H20 mmRoHS compliantApplicationsPM2.5 particulate monitoring in dusty outdoor environments with CL-220 series sensorsMaintenance of CL-220 series modules where minimal downtime is required
The FLT-C004 is a replaceable circular filter patch, supplied as a pack of six, designed for the DLW-1000 series. It lets you renew the protective patch in the field instead of sending a clogged unit back for repair.PM2.5 sensors used outdoors take in dusty air, and aerosol can block the measuring channel, leading to persistent high-concentration alarms and unreliable readings. Swapping the patch restores the sensor's air path while the device stays installed, which reduces downtime and the cost of repair.Circular patch, OD 35.5 mm, ID 30.6 mmPack of 6 replacement patchesReplaced without uninstalling the DLW-1000 unitDesigned for the DLW-1000 series with PM2.5 sensingApplicationsOutdoor PM2.5 air quality monitoring in dusty environmentsOngoing maintenance of DLW-1000 series installations
FRnet I/O Module with 32-channel Relay.
Handheld Controller with 512k flash ,512k SRAM, CPU is 40MHz.
M2M RTU series management software.
PROFINET I/O Module (10-channel Universal Analog Input Module). Includes a DB-1820 daughter board.
19" Rack Mounting Kit 3U.
SMS Monitor/Database System Software for GT-53x series.