DN-848VI-10V 8-Channel Voltage Attenuator, ±10 Vpp with Channel Isolation
8-channel ±10 Vpp AC/DC voltage attenuator with 3000 VDC channel-to-channel isolation, for scaling high-voltage signals to analogue input modules such as I-7017.
- 8 channels of AC/DC voltage attenuation to ±10 Vpp output
- Linear attenuation ratio for high-voltage input measurement
- 3000 VDC intra-module and channel-to-channel isolation
- Input impedance above 1 MΩ with 1% of FSR accuracy
- 30 kHz bandwidth
- Powered from +10 to +30 VDC
5 837,57 kr per st.
| 1–9 st. | 5 837,57 kr | |
|---|---|---|
| 10–30 st. | 5 660,67 kr | −3 % |
| 31+ st. | 5 550,11 kr | −5 % |
Produktinformation "DN-848VI-10V 8-Channel Voltage Attenuator, ±10 Vpp with Channel Isolation"
The DN-848VI-10V CR is an 8-channel voltage attenuator for AC and DC signals, rated at ±10 Vpp. It lets engineers measure high-voltage inputs with standard analogue input modules, with a linear attenuation ratio across the channels.
The I-variant provides 3000 VDC intra-module isolation and 3000 VDC channel-to-channel isolation, which helps prevent noise from passing between inputs and outputs or between channels. Input impedance is above 1 MΩ, and the channels have a 30 kHz bandwidth and 1% of FSR accuracy.
The module runs from a +10 to +30 VDC supply, has a plastic casing and mounts on a DIN rail. It is suited to use with analogue input modules such as the I-7017 and I-87017 for high-voltage measurement.
Applications
- High-voltage measurement with analogue input modules such as I-7017 and I-87017
- Signal conditioning for industrial data acquisition
| Product type: | Voltage Attenuator |
|---|---|
| Analog inputs: | 8 |
| Analog outputs: | 8 |
| Isolation: | 3000 VDC |
| Power input: | +10 ~ +30 VDC |
| Operating temperature: | -25 ~ +75 °C |
| Mounting: | DIN-rail |
| Housing: | Plastic |
Specifikationer
| EMS Protection | |
|---|---|
| ESD (IEC 61000-4-2) | ±4 kV contact for power line, input and output channels, ±8 kV air for random point |
| Surge (IEC 61000-4-5) | ±3 kV for power liner |
| Analog Input | |
| Channels | 3 : DN-843V-600V, DN-843VI-600V 8 : DN-848VI-10V, DN-848VI-80V, DN-848VI-150V |
| Type | AC/DC Voltage |
| Range | ±10 ~ ±800 Vpp |
| Accuracy | 1% of FSR |
| Bandwidth | 30 KHz : DN-848VI-10V, DN-848VI-80V, DN-848VI-150V 100 KHz : DN-843V-600V, DN-843VI-600V |
| Input Impedance | >1 MΩ |
| Channel-to-Channel Isolation | 3000 VDC (except DN-843V-600V) |
| Intra-module Isolation | 3000 VDC (except DN-843V-600V) |
| Analog Output | |
| Channels | 3 : DN-843V-600V, DN-843VI-600V 8 : DN-848VI-10V, DN-848VI-80V, DN-848VI-150V |
| Type | AC/DC Voltage |
| Range | ±10 Vpp |
| Power | |
| Input Range | +10 ~ +30 VDC |
| Consumption | 0.56 W : DN-843V-600V 3.84 W : DN-843VI-600V 9.2 W : DN-848VI-10V, DN-848VI-80V, DN-848VI-150V |
| Mechanical | |
| Casing | Plastic |
| Dimensions (mm) | 174 x 122 x 25 (W x L x D) : DN-843V-600V, DN-843VI-600V 174 x 122 x 33 (W x L x D) : DN-848VI-10V, DN-848VI-80V, DN-848VI-150V |
| Installation | DIN-Rail Mounting |
| Environment | |
| Operating Temperature | -25 ~ +75 °C |
| Storage Temperature | -30 ~ +75 °C |
| Humidity | 10 ~ 90% RH, Non-condensing |
Specifikationer enligt tillverkaren. Ändringar förbehålls.